11 research outputs found

    Contribution Ă  l’amĂ©lioration de la prĂ©cision absolue des robots parallĂšles

    Get PDF
    Le but de la prĂ©sente Ă©tude est de contribuer Ă  l’amĂ©lioration de la prĂ©cision absolue des robots parallĂšles, en ayant recours aux mĂ©thodes d’étalonnage gĂ©omĂ©trique. Ces mĂ©thodes consistent Ă  identifier les valeurs des paramĂštres gĂ©omĂ©triques du robot, en vue d’amĂ©liorer la correspondance entre le robot rĂ©el et le modĂšle mathĂ©matique utilisĂ© par son contrĂŽleur. En plus de la compensation des erreurs gĂ©omĂ©triques, les opĂ©rations d’étalonnage proposĂ©es permettent d’identifier prĂ©cisĂ©ment le rĂ©fĂ©rentiel de base de chaque robot Ă©tudiĂ©. Les mĂ©thodes dĂ©veloppĂ©es sont appliquĂ©es Ă  deux robots parallĂšles Ă  moins de six degrĂ©s de libertĂ© (ddl) : une table de positionnement prĂ©cis Ă  trois ddl (PreXYT) et un robot plan cinqbarres (DexTAR) Ă  deux ddl. Pour le premier robot, l’étalonnage est effectuĂ© en utilisant d’abord une mĂ©thode d’identification directe. Le deuxiĂšme travail destinĂ©e Ă  amĂ©liorer la prĂ©cision absolue du PreXYT rĂ©sulte de la mĂ©thode gĂ©omĂ©trique directe d’étalonnage. En ce qui concerne le robot DexTAR, sa prĂ©cision est amĂ©liorĂ©e en utilisant une approche d’autoĂ©talonnage qui exploite les modes de fonctionnement et les modes d’assemblage, pour rĂ©duire le nombre de positions d’étalonnage. Cette approche est particuliĂšrement intĂ©ressante pour sa simplicitĂ© : Ă  chaque position d’étalonnage une sphĂšre de prĂ©cision est installĂ©e en permanence pour servir de cible de mesure. Les positions de ces billes, placĂ©es sur une plateforme amovible, n’est mesurĂ©e qu’une seule fois, en utilisant une machine de mesure tridimensionnel (MMT). AprĂšs la rĂ©installation de la plateforme sur la base du robot, l’étalonnage peut se faire n’importe quand en n’utilisant que les informations provenant des encodeurs des actionneurs. Les donnĂ©es d’étalonnage et de validation des rĂ©sultats sont rĂ©coltĂ©es en utilisant deux appareils mesurant par palpage. Le premier appareil est un bras articulĂ© de mesure de coordonnĂ©es, de la compagnie FARO Technologies ; le second est une MMT de la compagnie Mitutoyo. Les incertitudes de mesures de ces machines sont respectivement ±18 ÎŒm et ±2,7 ÎŒm (niveau de confiance de 95%). Sachant que la qualitĂ© de l’étalonnage est inversement proportionnelle aux incertitudes de mesures, l’utilisation d’instruments prĂ©cis avec des modĂšles gĂ©omĂ©triques d’étalonnage quasi-complet nous a permis d’atteindre ces rĂ©sultats : les erreurs maximales en position et en orientation ont Ă©tĂ© rĂ©duites respectivement Ă  0,044 mm et 0,009° pour le PreXYT, Ă  l’intĂ©rieur d’un cercle de 170 mm de diamĂštre. Pour le robot DexTAR, l’erreur maximale de position a Ă©tĂ© rĂ©duite Ă  0,080 mm dans l’ensemble de son espace de travail, soit une zone d’environ 600 mm × 600 mm. AmĂ©liorer la prĂ©cision des robots au-delĂ  de ces valeurs, en utilisant juste les approches gĂ©omĂ©triques, pourrait s’avĂ©rer peu probable. En ce sens, l’ajout de la modĂ©lisation et la compensation des erreurs non gĂ©omĂ©triques serait utile pour obtenir des rĂ©sultats meilleurs

    Online pose correction of an industrial robot using an optical coordinate measure machine system

    Get PDF
    In this article, a dynamic pose correction scheme is proposed to enhance the pose accuracy of industrial robots. The dynamic pose correction scheme uses the dynamic pose measurements as feedback to accurately guide the robot end-effector to the desired pose. The pose is measured online with an optical coordinate measure machine, that is, C-Track 780 from Creaform. A root mean square method is proposed to filter the noise from the pose measurements. The dynamic pose correction scheme adopts proportional-integral-derivaitve controller and generates commands to the FANUC robot controller. The developed dynamic pose correction scheme has been tested on two industrial robots, FANUC LR Mate 200iC and FANUC M20iA. The experimental results on both robots demonstrate that the robots can reach the desired pose with an accuracy of ±0.050 mm for position and ±0.050° for orientation. As a result, the developed pose correction can make the industrial robots meet higher accuracy requirement in the applications such as riveting, drilling, and spot welding

    Amélioration de la flexibilité et de la robustesse des systÚmes transitiques

    Get PDF
    Flexibilité et efficacité des ST -- Réingénierie et robustesse des ST -- Méthodologie -- Amélioration de la robustesse d'un ST -- Programme de test du ST -- Mode semi-automatique -- Mode manuel

    Impedance Control Self-Calibration of a Collaborative Robot Using Kinematic Coupling

    No full text
    This paper presents a closed-loop calibration approach using impedance control. The process is managed by a data communication architecture based on open-source tools and designed for adaptability. The calibration procedure uses precision spheres and a kinematic coupling standard machine tool components, which are suitable for harsh industrial environments. As such, the required equipment is low cost (approximately $2000 USD), robust, and is quick to set up, especially when compared to traditional calibration devices. As demonstrated through an experimental study and validated with a laser tracker, the absolute accuracy of the KUKA LBR iiwa robot was improved to a maximum error of 0.990 mm, representing a 58.4% improvement when compared to the nominal model. Further testing showed that a traditional calibration using a laser tracker only improved the maximum error by 58 µm over the impedance control approach

    Use of a Force-Torque Sensor for Self-Calibration of a 6-DOF Medical Robot

    No full text
    The aim of this paper is to improve the position accuracy of a six degree of freedom medical robot. The improvement in accuracy is achieved without the use of any external measurement device. Instead, this work presents a novel calibration approach based on using an embedded force-torque sensor to identify the robot’s kinematic parameters and thereby enhance the positioning accuracy. A simulation study demonstrated that our calibration approach is effective, whether or not any measurement noise is present: the position error is improved, inside the robot target workspace, from 12 mm to 0.320 mm, for the maximum values, and from 9 mm to 0.2771 mm, for the mean errors